Biomarkers and Bioinformatics Poster Presentation

P0083 - Gadolinium improves detection of central vein lesions in MS using 3T FLAIR*. (ID 1404)

Speakers
  • L. Daboul
Authors
  • L. Daboul
  • C. O'Donnell
  • D. Moreno-Dominguez
  • P. Rodrigues
  • J. Derbyshire
  • C. Azevedo
  • A. Bar-Or
  • E. Caverzasi
  • P. Calabresi
  • B. Cree
  • L. Freeman
  • R. Henry
  • E. Longbrake
  • J. Oh
  • N. Papinutto
  • D. Pelletier
  • R. Samudralwar
  • M. Schindler
  • E. Sotirchos
  • N. Sicotte
  • A. Solomon
  • R. Shinohara
  • D. Reich
  • P. Sati
  • D. Ontaneda
Presentation Number
P0083
Presentation Topic
Biomarkers and Bioinformatics

Abstract

Background

The central vein sign (CVS) is a proposed MRI diagnostic biomarker for multiple sclerosis (MS). Use of gadolinium (Gd) in the CVS literature has been inconsistent, and it is unknown whether Gd improves detection of CVS when using FLAIR*.

Objectives

To determine if, and to what extent, gadolinium injection improves detection of CVS lesions when using FLAIR* imaging.

Methods

A cross-sectional multicenter study recruited adults clinically and/or radiologically suspected of having MS. High-isotropic-resolution, T2*-weighted segmented echo-planar imaging (T2*-EPI) was acquired pre- and post-injection of Gd-based contrast agent at 3T; pre-Gd 3D FLAIR images were also acquired. T2*-EPI and FLAIR images were processed on the QMENTA platform to generate FLAIR* images. FLAIR* pre-Gd and post-Gd scans from this substudy of 30 patients at 5 sites were analyzed. FLAIR images were used to create T2 lesion masks. Subsequently, FLAIR* images were evaluated in a random order. Lesions were categorized as CVS+, CVS-, or excluded based on the North American Imaging in MS (NAIMS) Criteria by two trained raters blinded to clinical data and Gd use. The proportion of CVS+ lesions was calculated for each scan, and differences in CVS detection based on Gd use were assessed by a Wilcoxon rank-sum test. Diagnostic performance was compared against McDonald 2017 Criteria.

Results

The mean participant age was 45 years (SD: 12); 23 (77%) were women. 14 (47%) met McDonald 2017 Criteria for MS, while 16 (53%) did not (“non-MS”). A total of 487 CVS+ lesions and 976 CVS- lesions were evaluated. The percentage of CVS+ lesions post-Gd in the MS group (median 67% [IQR 30%]) was higher than pre-Gd (41% [47%], p<0.001). There was no apparent difference in percentage of CVS+ lesion in the non-MS group (post-Gd: 10% [23%]; pre-Gd: 5% [29%]; p=0.1). In the MS group, 12/14 (86%) had ≥40% CVS+ lesions on post-Gd imaging, whereas only 8/14 (57%) exceeded that threshold on pre-Gd imaging. When evaluating CVS performance using the 40% CVS+ threshold, the sensitivity and specificity of the CVS post-Gd for MS were 86% and 81%, respectively, compared to 54% and 86% pre-Gd.

Conclusions

The detection of the CVS using FLAIR* at 3T is improved when Gd is used. Based on these results, a multicenter prospective CVS diagnostic study, sponsored by NINDS and NAIMS, will use Gd in the study protocol. Future clinical use of the CVS should balance the increased costs and potential risks of Gd use with the risks of misdiagnosis due to missing CVS on non-contrast imaging.