Background

Circulating tumor cell (CTC) detection methods based on epithelial cell adhesion molecule (EpCAM) have low detection rates in epithelial ovarian cancer (EOC). Meanwhile, folate receptor alpha (FRα) has high expression in EOC cells. We explored the feasibility of combining FRα and EpCAM as CTC capture targets in EOC.

Methods

EpCAM and FRα antibodies were linked to magnetic nanospheres (MNs) using the principle of carbodiimide chemistry. Blood samples from healthy donor spiked with A2780 ovarian cancer cells were used for detecting the capture rate. Ninety-five blood samples from 30 patients with EOC were used for comparing the positive rate of detection when using anti-EpCAM-MNs alone with that when using combination of anti-EpCAM-MNs and anti-FRα-MNs. Samples from 28 patients initially diagnosed with EOC and who did not undergo any treatment and 20 patients with ovarian benign disease were used for evaluating the sensitivity and specificity of combination of anti-EpCAM-MNs and anti-FRα-MNs.

Results

Regression analysis between the number of recovered and that of spiked A2780 cells revealed yEpCAM = 0.535x (R2 = 0.99), yFRα = 0.901x (R2 = 0.99) and yEpCAM+FRα = 0.928x (R2 = 0.99). In mixtures of A2780 and MCF7 cells, the capture rate was 92% using the combination of anti-EpCAM-MNs and anti-FRα-MNs, exceeding the rate when using anti-EpCAM-MNs or anti-FRα-MNs alone by approximately 20% (P < 0.01). The combination of anti-EpCAM-MNs and anti-FRα-MNs showed significantly increased positive rate compared with anti-EpCAM-MNs alone (χ2 = 14.45, P < 0.001). Sensitivity values were 0.536 and 0.75 when using anti-EpCAM-MNs alone and when using the combination of anti-EpCAM-MNs and anti-FRα-MNs, respectively. Specificity values were 0.9 and 0.85, respectively. The combination of anti-EpCAM-MNs and anti-FRα-MNs improved the sensitivity of CTC detection in patients with newly diagnosed EOC (χ2 = 4.17; P = 0.041).

Conclusions

The combination of FRα and EpCAM is feasible as a CTC capture target of CTC detection in patients with EOC.